• Latest
  • All
  • News
  • Business

How to Test Electrical Ring Main Circuits

May 5, 2018
What Is a PDF Virus?

What Is a PDF Virus?

May 17, 2022
The Ultimate Guide to TV Antenna Installation

The Ultimate Guide to TV Antenna Installation

May 17, 2022
How to create multiple email filters in ProtonMail free plan

How to create multiple email filters in ProtonMail free plan

May 14, 2022
6 Benefits of Outsourcing Your Business’s Design and Development Projects

6 Benefits of Outsourcing Your Business’s Design and Development Projects

May 13, 2022
How IoT, Autonomous Cars and Smart Cities Will Develop

How IoT, Autonomous Cars and Smart Cities Will Develop

May 10, 2022
Apple Virus Guide: How to Get Rid of a Virus on Your iPhone

How to transfer photos from iPhone to Computer

May 10, 2022
How Does Data Analytics Improve Security Systems?

How Does Data Analytics Improve Security Systems?

May 4, 2022
Discovery Phase For Software Development: How Much Does It Cost?

Discovery Phase For Software Development: How Much Does It Cost?

May 4, 2022
Smart Contract Programming Languages in Blockchain

Smart Contract Programming Languages in Blockchain

May 4, 2022
How Does an Elasticsearch Application Work?

How Does an Elasticsearch Application Work?

May 3, 2022
How To Take Care of Files on Your Computer

The Many Benefits That External IT Support Provides For All Businesses.

May 2, 2022
In Order To Avoid Business Downtime – You Require IT Consulting

In Order To Avoid Business Downtime – You Require IT Consulting

May 2, 2022
  • Guest Posts
  • Advertise
  • Contact Us
  • Privacy Policy
Wednesday, May 18, 2022
Tech Featured
  • Home
  • Latest Tech
  • Apple
  • How to’s
  • Apps
  • Automobiles
  • Gadgets
  • Gaming
  • Reviews
  • Tech Tips
No Result
View All Result
Tech Featured
No Result
View All Result
Home News

How to Test Electrical Ring Main Circuits

by techfeatured
May 5, 2018
in News
0
3
SHARES
129
VIEWS
Share on FacebookShare on Twitter

The UK was the first and is now is probably the only country in the world which still uses the 30 amp ring system for wiring socket outlets in electrical installations. The ring main circuit has long been the subject of many a heated discussion between electrical experts, but as an electrician you’ll no doubt need to test them in the course of your duties. Here is an overview of Ring Main inspection and testing procedures.

Warning- Please note that this is a ‘dead’ test so the distribution board, consumer unit or circuit must be isolated from the electrical supply. To begin with you’ll need to carry out a Safe Isolation Procedure and get permission to turn off the supply.

Here’s the testing procedure:

Insulation Resistance

Disconnect all appliances and accessories from the ring circuit and carry out insulation tests between the Line, Neutral and Earth CPC.

End to End Ring Continuity Test

Set your test meter to low resistance range and ‘zero’ the test leads. Measure the resistance of ring continuity of each of the live, neutral and earth conductor ring loops. Record these end to end readings for future reference and entering onto a test sheet. Note that where the earth conductors are smaller, the resistance will obviously be higher. For example for twin and earth cables 1.5mm will be 1.66 times higher than 2.5mm.

Super Loop Test L&N

Cross connect the live and neutral conductors from opposite ends of the ring and to form a super loop. If at first this sounds confusing, try drawing the live and neutral loops of a ring circuit on a piece of paper with the opposite ends connected. You’ll see that it forms one big super loop.

Test resistance between the ends you have just connected together. The reading taken between the super loop ends should be about half that of your previous continuity reading. You can then verify the ring main wiring and connections by going to each socket outlet and testing between live and neutral. Where the socket is on the ring and the connections are ‘good’, your readings should be within 0.05 of your original super loop reading at the distribution board.

These readings are not normally recorded but will form the basis for your assessment of the ring main circuit connections.

High readings could indicate that the socket is on a spur from the ring, that connections need tightening or that the socket is faulty giving a poor connection to the plug and needs replacing. Where the readings are not consistent this could indicate that there are cross connections and the ring circuit has been bridged.

Super Loop Test L&E

Cross connect the line and earth conductors from opposite ends of the ring and to form a super loop. Test between the two sets of ends you have just connected together. The resistance reading should be about half that of your previous continuity reading. You can then verify the ring main wiring and connections by measuring the resistance at each socket outlet as for Live and Neutral described previously. Testing between live and earth at the sockets also checks for correct polarity.

Tags: CircuitsElectricalMainRingTest
Share1Tweet1

For any queries, you can reach us at [email protected]

Latest Posts

  • What Is a PDF Virus?
  • The Ultimate Guide to TV Antenna Installation
  • How to create multiple email filters in ProtonMail free plan
  • 6 Benefits of Outsourcing Your Business’s Design and Development Projects
  • How IoT, Autonomous Cars and Smart Cities Will Develop
Tech Featured

© 2022. All Rights Reserved.

Navigate Site

  • Guest Posts
  • Advertise
  • Contact Us
  • Privacy Policy

Follow Us

No Result
View All Result
  • Home
  • Latest Tech
  • Apple
  • How to’s
  • Apps
  • Automobiles
  • Gadgets
  • Gaming
  • Reviews
  • Tech Tips

© 2022. All Rights Reserved.